carotene: clamp left-edge weight in downsample_bilinear_8uc1 - #30022
For the leftmost pixel the sample coordinate c = 0.5*wr - 0.5 can be negative, so the left-column weight overflows full-scale and interpolation extrapolates beyond the source, corrupting the first output column.
Clamp the weight to full-scale when c < 0, matching the scalar/OpenCL edge handling. Affects both the 16- and 8-wide column loops.
### Pull Request Readiness Checklist
See details at https://github.com/opencv/opencv/wiki/How_to_contribute#making-a-good-pull-request
- [x] I agree to contribute to the project under Apache 2 License.
- [x] To the best of my knowledge, the proposed patch is not based on a code under GPL or another license that is incompatible with OpenCV
- [ ] The PR is proposed to the proper branch
- [ ] There is a reference to the original bug report and related work
- [ ] There is accuracy test, performance test and test data in opencv_extra repository, if applicable
Patch to opencv_extra has the same branch name.
- [ ] The feature is well documented and sample code can be built with the project CMake