mirror of
https://github.com/opencv/opencv.git
synced 2026-11-16 06:17:53 -06:00
Document that fisheye::calibrate forces a fixed K1..K4 coefficient to 0 even when CALIB_USE_INTRINSIC_GUESS supplies a guess for it, and that CALIB_FIX_INTRINSIC overrides CALIB_FIX_K1..K4 in stereoCalibrate. Note that the default Schur-complement engine in calibrate() sums per-view contributions in parallel, so repeated calls are not bit reproducible; CALIB_DISABLE_SCHUR_COMPLEMENT does not have this issue. Correct the CALIB_USE_INTRINSIC_GUESS docs for fisheye::calibrate and fisheye::stereoCalibrate: skew and k1..k4 must also be initialized, and the default focal length is max(width,height)/2, not /pi. Document that undistortPoints() runs a fixed 5 iterations by default and never checks its 0.01 epsilon unless TermCriteria::EPS is set in the passed criteria, and clarify that fisheye::undistortPoints' default epsilon is an angular threshold, not comparable to undistortPoints' pixel-space one. Also name the criteria parameter in undistortImagePoints().